Frequency control of the variable frequency speed range of the pump three major factors

August 31, 2023
Pump speed is generally slow down the problem. When the use of frequency control, the original design by the frequency of the state of the pump and motor operating parameters have undergone major changes, the other as pipeline characteristics curve, speed governor pump in parallel with the constant speed pump and other factors, will be Speed ​​range has a certain impact. Out of range speed control is difficult to achieve the purpose of energy conservation. Therefore, frequency conversion speed regulation can not be unlimited. Generally believed that the frequency control speed should not be lower than the rated speed of 50%, preferably at 75% to 100%, and should be combined with the actual calculation. 1, the pump process characteristics of the speed range In theory, the pump speed efficient area through the frequency-efficient area around the end of two similar conditions parabolic middle area OA1A2. In fact, when the pump speed is too small, the efficiency of the pump will drop sharply. Affected by this, the high-speed pump governor shrank to PA1A2 [2]. Obviously, if the operating point has exceeded this area, Therefore, the minimum speed can be obtained as follows: Since the conditions at point C and point A1 are similar, according to the proportional law: (QC / Q1) 2 = HC / H1 The point C is on the curve H = H0 + S? Q2 There are: HC = H0 + S? QC2 Where, HC, QC is unknown, the solution equation: HC = H1 × H0 / (H1-S? Q12) QC = Q1 × [H0 / (H1-S? Q12) / 2 According to the proportional law: nmin = n0 × [H0 / (H1-S? Q12)] 1/2 2, the fixed speed pump on the speed range In practice, the water supply system is often multiple pumps in parallel. Due to the expensive investment, it is impossible to speed up all the pumps, so the general speed pump, fixed speed pump mixed water supply. In such a system, care should be taken to ensure that both the variable speed pump and the fixed speed pump operate at the high efficiency stage and achieve the optimum system. At this moment, the constant speed pump has a great influence on the speed regulating range of the speed regulating pump running in parallel with it [2]. The main points of the following two situations: 2.1 with the same type of pump must be run side by side, although the scheduling flexibility, but can not take into account the speed pump and the constant speed pump efficient work section, therefore, in this case speed range is tiny. 2.2 different models of a pump must be run side by side, if it can reach the speed of the pump at the rated speed when the right end of the head and the high-speed section of the left end of the pump lift equal. You can achieve the maximum range of speed operation. However, at this moment, the speed regulating pump and the constant speed pump must not be allowed to run in parallel after the exchange. 3, the motor efficiency of the speed range In the case of similar conditions, the general Nαn3, so as the speed decreases, the shaft power will drop sharply, but if the motor output power is too much deviation from the rated power or operating frequency Excessive offset frequency, will make the motor efficiency drops too fast, eventually affecting the efficiency of the entire pump unit. And since the cold motor continuous low-speed operation, but also due to insufficient air volume affect the heat, threaten the safe operation of the motor.
Entre em contato conosco

Autor:

Mr. andysun

Phone/WhatsApp:

+8615861598173

Produtos populares
Você também pode gostar
Categorias relacionadas

Enviar e-mail para este fornecedor

Assunto:
E-mail:
mensagem:

Sua mensagem mss

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

enviar